b. Mill certification for structural bolts, framing steel,
roofing and siding, and steel wall liner panels.
c. Warranty certificate. At the completion of the project the
Contractor shall furnish signed copies of the 5 year Warranty for
Metal Building Roof System, a sample copy of which is attached to
this section, the 20-year Manufacturer's Material Warranties, and
the Manufacturer's 20-year System Weathertightness Warranty where
one is required.
Insulation
Certificate attesting that the polyisocyanurate insulation
furnished for the project contains recovered material, and showing
an estimated percent of such recovered material.
1.3
GENERAL REQUIREMENTS
**************************************************************************
NOTE: The structural steel design must meet the
requirements of OSHA Steel Erection Standard, 29 CFR
Part 1926, Subpart R-Steel Erection, Effective Date
January 18, 2002.
**************************************************************************
The metal building system covered under this specification shall be
provided by a single manufacturer and shall include all components and
assemblies that form a building. Structural Standing Seam Metal Roofing
System, when specified, shall be furnished as part of a single
manufacturer's system.
1.3.1
Building Configurations
**************************************************************************
Drawings will show roof slope in accordance with the
guidance provided in TI 809-29 based on the type of
roofing system specified. Drawings will show
required width and length dimensions from inside
face of wall covering; minimum inside clear
dimensions; size, type, and number of windows,
doors, louvers, ventilators, and skylight panels;
hardware requirements, if not scheduled in the
specifications, including requirements for door
weather stripping and thresholds; and other
information as required to supplement the
specifications.
**************************************************************************
Roof slope shall be as shown on the drawings. Buildings shall be
single-span structures with one of the following framing systems:
self-framing or rigid frame. [Exterior doors] [windows] [overhead doors]
[louvers] and [_____] shall be included in the metal building system.
Building shall be a manufacturer's advertised product, except that
dimensions shall be not less than those indicated. The minimum inside
clear dimensions shall be as shown on the drawings.
SECTION 13121