cleanings without reapplication. Renewable
treatments, however, must be reapplied periodically,
frequently after each cleaning, which imposes a
continuing maintenance burden. Permanent treatments
can be successfully applied to most fabrics. Only a
few fibers or fabrics are limited to renewable
treatments. Specify permanent treatment except
where the fiber type or other fabric characteristics
prohibit use of this type.
**************************************************************************
UL 214 or NFPA 701. Drapery fabric and lining shall pass the [small] [and]
[large] scale test. Treatment to enhance flame resistance shall be
[permanent] [renewable] type. If treated, fabric shall pass the [small]
[and] [large] scale test after being subjected to the accelerated dry
cleaning or laundering cycles specified in UL 214 or NFPA 701.
2.1.2
Sewing Thread
Pre-shrunk mercerized cotton (50/3) or monofilament in equivalent size,
except do not use monofilament in the heading.
2.1.3
Heading
2.1.3.1
Heading Hooks
Slip-in-type, bright zinc-plated, chromium-plated, or nickel-plated steel,
and of a size adequate to hold the heading upright. Provide one hook for
each pleat.
2.1.3.2
Snap-Tape System (Ripplefold)
Heavy vinyl or nylon tape with locking fasteners attached to tape to form
desired pleat spaces and fullness. Cut tapes to size and sew to drapery
fabric to form the heading.
2.1.4
Drapery Hardware
**************************************************************************
NOTE: Unless both stationary and traverse rods or
tracks are required, delete the type not to be used.
When traverse, indicate whether two or one-way draw;
when one-way, select whether left-to-right or
right-to-left.
**************************************************************************
**************************************************************************
NOTE: Permit Contractor's option of steel or
aluminum rods and tracks unless the desired finish
cannot be provided with both materials or the
installation dictates the use of one particular
material.
**************************************************************************
[Stationary] [and] [traverse] [wall-mounted rods] [and] [ceiling mounted
tracks] of heavy-duty type. [Traverse rods or tracks shall be manually
operated, [center close two-way] [one-way draw] [left-to-right]
[right-to-left]]. Rods and tracks shall be cold-rolled, commercial quality
steel minimum 0.75 mm 0.030 inch thick or extruded aluminum minimum 1.27 mm
SECTION 12491N
Page 8