compliance with the specified performance criteria, upon
completion and testing of the installed system. Each test report
shall indicate the final position of controls.
SD-07 Certificates
Motors
Manufacturer's certificates attesting that the motors meet the
NFPA 70 requirements for the hazardous area classification.
Manufacturer's Field Representative
Names and qualifications of each manufacturer's field
representative and training engineer with written certification
from the manufacturer that each representative and trainer is
technically qualified.
SD-10 Operation and Maintenance Data
Thermal Oxidation System
Maintenance
with step-by-step procedures and sequences for system startup,
operation and shutdown. The instructions shall include the
manufacturer's name, model number, service manual, parts list, and
brief description of all equipment and the operating features of
each element. The instructions shall include as-built drawings of
the piping layout, equipment layout, and simplified wiring and
control diagrams of the system as installed. Automatic controls,
functional logic, control loops, set points and alarm signals
shall be described. Flow diagrams shall be included in the
instructions.
[Six] [_____] complete copies of maintenance instructions
listing maintenance procedures, possible breakdowns and repairs,
and trouble shooting guides.
1.4
SYSTEM DESCRIPTION
The thermal (catalytic) oxidation system shall be a complete unit process
for destruction of organic contaminants carried in the [off-gas] [vapor
phase]. Equipment shall include, but shall not be limited to, a complete
and operational thermal oxidation system, including supporting equipment
and accessories.
1.4.1
**************************************************************************
NOTE: Find the wind speed and seismic zone for the
stack design in ASCE 7.
**************************************************************************
The thermal oxidation system shall conform to section 60.18 of 40 CFR 60.
Vertical and lateral supports for the stack shall be in accordance with
NFPA 82 and NFPA 211, as applicable, for the wind forces indicated. The
system shall be designed for the following parameters:
SECTION 11378