(Ratio of oxygen delivered to the ozone
to the oxygen generator)
Cycle time (adjustable range)
[_____] minutes
Hydrocarbon concentration to ozone
[0] [3] [_____] ppm
Discharge pressure to ozone generator
[_____] kPa psi
[480] [_____] volt, 3 phase,
60 hertz.
Cooling water supply (max. temperature)
[_____] degrees C F
Cooling water flow rate (maximum)
[_____] L/s gpm
Adsorption vessels shall be designed and constructed in accordance with
ASME BPVC SEC VIII D1.
2.2.2
Liquid Oxygen (LOX) Storage and Supply System
**************************************************************************
NOTE: Provide seismic requirements for piping,
tanks and related equipment supports, if a
Government designer is the Engineer of Record, and
show on the drawings. Delete the inappropriate
bracketed phrase. Sections 13080 and 15070,
properly edited, must be enclosed in the contract
documents.
**************************************************************************
LOX storage system and associated equipment shall comply with NFPA 50 and
CGA G-4.4. Tanks, vaporizers and regulators shall be suitable for exterior
installations. Cleaning for components, equipment, valves, piping and
tanks for oxygen service shall be accomplished in accordance with CGA G-4.1,
CGA HB. The system shall be rated to withstand a minimum wind speed of
[_____] km miles per hour, maximum ambient temperature [_____] degrees C F,
and [_____] meters feet mean sea level altitude. System shall be supported
and braced to resist seismic loads [as specified in Sections 13080 SEISMIC
PROTECTION FOR MISCELLANEOUS EQUIPMENT and 15070A SEISMIC PROTECTION FOR
MECHANICAL EQUIPMENT] [as indicated].
2.2.2.1
LOX Storage Tanks
**************************************************************************
NOTE: Typically, 304 stainless steel is used for
LOX inner tanks less than 6000 L (1500 gallons) or
6750 kg (15,000 pounds), while 9 percent nickel
units are generally specified for larger tanks
principally due to economic considerations. Typical
generally be less than 515 kPa (75 psi); significant
cost savings can be achieved by reducing the tank
pressure requirements, but lower pressure tanks may
require a longer lead time to procure since the
1.2/1.7 MPa (175/250 psi) tanks are most commonly
SECTION 11377
Page 20