with ASTM D 3951. Doors, windows, and louvers shall be handled carefully
to prevent damage to the faces, edges, corners, ends, and glazing.
Abraded, scarred, or rusty areas shall be cleaned, repaired, or replaced
immediately upon detection. Damaged components that cannot be restored to
like-new condition shall be replaced. Components and equipment shall be
stored in a dry location on platforms or pallets that are ventilated
adequately, free of dust, water, and other contaminants, and stored in a
manner which permits easy access for inspection and handling.
1.7
WARRANTY
Manufacturer's warranty for [_____] [5] years shall be furnished for
glazing materials. Warranty shall provide for replacement and installation
of glazing if delamination, discoloration, or cracking, or crazing occurs.
PART 2
PRODUCTS
2.1
GENERAL
Bullet-resistant component assemblies shall be of size and type indicated
and shall be provided at locations shown. All items included for exterior
installation shall be designed to resist water penetration or entrapment.
2.2
ELECTRICAL WIRING
Electrical wiring and conduit shall be provided as specified in Section
16402 INTERIOR DISTRIBUTION SYSTEM.
2.3
All ferrous metal components except stainless steel shall be furnished
primed for painting unless indicated otherwise. Finish painting shall be
in accordance with Section 09900 PAINTS AND COATINGS unless otherwise
indicated. Aluminum items shall be finished in standard mill finish unless
otherwise specified. When anodic coatings are specified, the coatings
shall conform to AAMA 611, with coating thickness not less than that
specified for protective and decorative type finish in AA DAF-45. Items to
be anodized shall receive a polished satin finish pretreatment and a clear
lacquer overcoat.
2.4
BULLET-RESISTANT STEEL PERSONNEL DOORS
Door/frame assemblies shall be factory fabricated units, designed to be
bullet resistant to the specified threat level, and shall conform to
applicable requirements of NAAMM HMMA 810, NAAMM HMMA 820, NAAMM HMMA 862,
this section, and requirements indicated on drawings. Frames shall be
furnished by the door fabricator. Door silencers shall be provided to
cushion the impact of the door on the frame so that steel to steel contact
is not made during closing. Exterior doors shall be completely
weatherstripped, weatherproof, and fully insulated. Exterior doors shall
close at flush top and bottom edges. Tops of doors shall be sealed against
water penetration.
2.4.1
Fire Rated Doors
Fire rated doors shall be provided at locations shown on the drawings.
Door assemblies shall bear the identifying label of the Underwriters
Laboratories, or a nationally recognized testing agency qualified to
perform certificate programs, indicating that the units conform to the
SECTION 11035
Page 18