Level Within Test
Minimum Attack
_________________
______________
Component
Test Standard
Standard (If Any)
Time (Minutes)
_________
_____________
_________________
______________
[[_____]
SD Std-01.01
15 Minute
15]
[[_____]
SD Std-01.01
60 Minute
60]
1.6
QUALIFICATIONS
Welding procedures, welders, and welding operators shall be qualified in
accordance with AWS D1.1/D1.1M.
1.7
DELIVERY, STORAGE, AND HANDLING
Components shall be delivered to the job site with the manufacturer, name,
and model number clearly marked thereon. Components shall be delivered,
stored, and handled so as not to be damaged or deformed and shall be in
accordance with ASTM D 3951. Components shall be handled carefully to
prevent damage to the faces, edges, corners, ends, and glazing where
applicable. Abraded, scarred, or rusty areas shall be cleaned, repaired,
or replaced immediately upon detection of the damage. Damaged components
that cannot be restored shall be replaced. Components and equipment shall
be stored in a dry location on platforms or pallets that are ventilated
adequately, free of dust, water, and other contaminants, and stored in a
manner which permits easy access for inspection and handling.
1.8
SEQUENCING AND SCHEDULING
When testing of a previously untested component is specified, sufficient
lead time shall be allowed so that testing will not delay construction.
The test results and component shall be approved by the Contracting Officer
before delivery of the component to the job site.
1.9
WARRANTY
**************************************************************************
NOTE: A warranty for all glazings should be
specified. The designer will determine availability
of warranty.
**************************************************************************
Manufacturer's warranty for [_____] [5] years shall be furnished for
glazing materials. Warranty shall provide for replacement and installation
of glazing if delamination, discoloration, or cracking or crazing occurs.
PART 2
PRODUCTS
2.1
FORCED ENTRY RESISTANT PERSONNEL DOOR AND FRAME ASSEMBLIES
Doors and frames shall be factory fabricated assemblies. Sizes shall be as
indicated. Doors shall be of steel, hardened steel, or be reinforced
internally with steel shapes and clad with aluminum. Interior composition
and reinforcement shall be determined by the manufacturer. Rubber
silencers shall be installed on door frames. Exterior doors shall have top
edges closed flush and sealed against water penetration, be insulated, and
shall be provided with weatherstripping and thresholds. Locks and hinges
SECTION 11025
Page 18