the manufacturer's standard finish. The day gate shall not interfere with
the operation of vault door inner escape device.
PART 3
EXECUTION
3.1
INSTALLATION
**************************************************************************
NOTE: The door frame is a nongrout type and is
adaptable to walls of 150, 200, 250, or 300 mm (6,
8, 10, or 12 inch) thickness with a 13 mm (1/2 inch)
tolerance. Where required, the availability of
frames to accommodate thicker walls should be
verified with manufacturers. Construction and wall
opening size requirements will vary between
manufacturers. There is no need to detail the door
or frame; however, the walls must be detailed as
necessary to show reinforcing. Wall opening sizes
should be shown as "approximate," with the final
size to be as determined by the vault door
manufacturer.
**************************************************************************
The vault door assembly shall be installed in strict compliance with the
printed instructions and drawings provided by the manufacturer. The day
gate shall be installed in a manner that will not interfere with operation
of the release handle on the inside of the vault door. After installation,
the door, the locking mechanism, and the inner escape device shall be
adjusted for proper operation.
-- End of Section --
SECTION 11020
Page 6