Manufacturer's catalog data including catalog cuts and
brochures. The data shall show that the proposed vault door unit
conforms with the requirements in FS AA-D-600, and has been tested
SD-07 Certificates
Vault Door and Frame[; G][; G, [_____]]
Certification shall state that vault-door units that do not bear
the GSA label are constructed to Class 5 standards.
SD-08 Manufacturer's Instructions
Installation
Printed instructions and drawings provided by the manufacturer.
1.3
GENERAL REQUIREMENTS
The vault door unit shall be a steel security-vault type door with frame,
[day gate], and ramp type threshold, and shall be a standard product of a
manufacturer specializing in this type of fabrication.
1.4
DELIVERY AND STORAGE
Door and frame assemblies shall be delivered to the jobsite in a protective
covering with the brand and name clearly marked thereon. Materials
delivered to the jobsite shall be inspected for damage, and unloaded with a
minimum of handling. Storage shall be in a dry location with adequate
ventilation, free from dust, water, and other contaminants, and which
permits easy access for inspection and handling. Door assemblies shall be
stored off the floor on nonabsorptive strips or wood platforms. Damage to
doors and frames shall be prevented during handling. Damaged items that
cannot be restored to like-new condition shall be replaced.
PART 2
PRODUCTS
2.1
VAULT DOOR AND FRAME
**************************************************************************
NOTE: Select the appropriate Type and Style
designation for the door, and delete inapplicable
portions. Although FS AA-D-600 covers both a Class
5 and a Class 6 door, only the Class 5 door is
presently available. Both the Class 5 and Class 6
doors afford protection for 20 man-hours against
surreptitious entry, 30 man-minutes against
attack. In addition, the Class 5 door affords
protection for 10 man-minutes against forced entry.
Type: Select the appropriate door type or types,
and delete those not applicable. "Right opening
swing" means hinges to the right when viewed from
outside the vault. Specify the optical device only
when requested by the Using Agency.
SECTION 11020
Page 4