of door frame to edge of sign shall be [
][as indicated on drawings][as
indicated on attachments]. Required blocking shall be installed. Signs
shall be installed on the wall adjacent to the latch side of the door.
Where there is no wall space to the latch side of the door, including at
double leaf doors, signs shall be placed on the nearest adjacent wall.
Mounting location for such signage shall be so that a person may approach
within 75 mm3 inches of signage without encountering protruding objects or
standing within the swing of a door. Signs on doors or other surfaces
shall not be installed until finishes on such surfaces have been installed.
Signs installed on glass surfaces shall be installed with matching blank
back-up plates in accordance with manufacturer's instructions.
[Illuminated signage shall be in conformance with the requirements of
Section 16510 INTERIOR LIGHTING.]
[SIGNAGE PLACEMENT SCHEDULE:
[DOOR]
[ROOM]
SIGN
[NUMBER
TYPE
TEXT
INSERT(S)
SYMBOL/REMARKS]]
3.1.1
Anchorage
Anchorage shall be in accordance with approved manufacturer's instructions.
Anchorage not otherwise specified or shown shall include slotted inserts,
expansion shields, and powder-driven fasteners when approved for concrete;
toggle bolts and through bolts for masonry; machine carriage bolts for
steel; lag bolts and screws for wood. Exposed anchor and fastener
materials shall be compatible with metal to which applied and shall have
matching color and finish. Where recommended by signage manufacturer, foam
tape pads may be used for anchorage. Foam tape pads shall be minimum 2 mm
1/16 inch thick closed cell vinyl foam with adhesive backing. Adhesive
shall be transparent, long aging, high tech formulation on two sides of the
vinyl foam. Adhesive surfaces shall be protected with a 0.13 mm 5 mil
green flatstock treated with silicone. Foam pads shall be sized for the
signage as per signage manufacturer's recommendations. Signs mounted to
painted gypsum board surfaces shall be removable for painting maintenance.
Signs mounted to lay-in ceiling grids shall be mounted with clip
connections to ceiling tees.
3.1.2
Protection and Cleaning
The work shall be protected against damage during construction. Hardware
and electrical equipment shall be adjusted for proper operation. Glass,
frames, and other sign surfaces shall be cleaned at completion of sign
installation in accordance with the manufacturer's approved instructions.
-- End of Section --