2.8
FABRICATION AND MANUFACTURE
2.8.1
Factory Workmanship
Holes for bolts and screws shall be drilled or punched. Drilling and
punching shall produce clean, true lines and surfaces. Exposed surfaces of
work shall have a smooth finish and exposed riveting shall be flush.
Fastenings shall be concealed where practicable.
2.8.2
Dissimilar Materials
Where dissimilar metals are in contact, the surfaces will be protected to
prevent galvanic or corrosive action.
**************************************************************************
NOTE: Editing of color reference sentence shall be
coordinated with the Government. Generally the
09915 Color Schedule or drawing is used when the
project is designed by an Architect or Interior
Designer. Color shall be selected from
manufacturer's standard colors or identified in this
specification only when the project is very simple
When the government directs that color be located in
the drawiangs a note shall be added that states:
"Where color is shown as being specific to one
manufacturer, an equivalent color by another
manufacturer may be submitted for approval.
Manufacturers and materials specified are not
intended to limit the selection of equal colors from
other manufacturers. The word "color" as used herin
includes surface color and pattern."
Prior to specifying a custom color finish, research
to determine if additional cost and lead time is
feasible. Note there is often a minimum order
requirement; this requirement will also affect
future orders.
Signage background color should be in high contrast
with signage copy. Dark background with light copy
is preferred.
**************************************************************************
2.9
COLOR, FINISH, AND CONTRAST
Color shall be [in accordance with Section 09915 COLOR SCHEDULE][as
indicated on the drawings][_____]. Finish of all signs shall be eggshell,
matte, or other non-glare finish as required in handicapped-accessible
buildings.
PART 3
EXECUTION
3.1
INSTALLATION
Signs shall be installed plumb and true and in accordance with approved
][schedule below][attachments]. Mounting height shall be 1.5 meters 60"
above the finish floor to the centerline of the sign. Distance from edge
SECTION 10440
Page 17