1.4.3.8
Roof Joint Sealant Compatibility
Provide manufacturer's certification that the selected joint sealant is
compatible with the epoxy primer.
1.4.3.9
Epoxy Coating Materials
Provide manufacturer's certification that the epoxy lining materials are
currently approved by the Naval Sea Systems Command and listed on the
Qualified Products Lists (QPL) for the specified materials.
1.4.3.10
Non-metallic Abrasive
Provide manufacturer's certification that the materials are currently
approved by the Naval Sea Systems Command and listed on the Qualified
Products Lists (QPL) for the specified materials.
1.4.3.11
Metallic Abrasive
Provide manufacturer's certification of conformance to contract
requirements and provide copies of test results.
1.4.4
Product Data
1.4.4.1
Roof Joint Sealant Instructions
Submit manufacturer's printed instructions including detailed mixing and
application procedures, minimum and maximum application temperatures, and
curing procedures. Include Materials Safety Data Sheets (MSDS) for
materials to be used at the job site in accordance with 29 CFR 1926.59.
1.4.4.2
Coating System Instructions
Submit manufacturer's printed instructions including detailed mixing and
application procedures, number and types of coats required, minimum and
maximum application temperatures, and curing procedures. Include Materials
Safety Data Sheets (MSDS) for materials to be used at the job site in
accordance with 29 CFR 1926.59.
1.5
DELIVERY AND STORAGE
Ship, store, and handle materials in accordance with SSPC PA 1, and as
modified in this Section. Maintain temperature in storage spaces between 5
and 24 degrees C 40 and 75 degrees F, and air temperature more than 3
degrees C 5 degrees F above the dew-point at all times. Inspect materials
for damage prior to use and return non-compliant materials to manufacturer.
immediately and notify the Contracting Officer. Expired materials may be
returned to manufacturer, tested, and if compliant, issued a shelf life
extension.
1.6
COATING HAZARDS
**************************************************************************
NOTE: This specification Section should be used
with NFGS-01525 "SAFETY REQUIREMENTS".
**************************************************************************
SECTION 09973