apply. Notify the Contracting Officer of any change in contractor
certification status.
][
**************************************************************************
NOTE: When using the contractor qualification
clause rather than the SSPC Certification
requirement, edit to require appropriate experience.
**************************************************************************
Submit the name, address, telephone number, FAX number, and e-mail address
of the contractor that will be performing all surface preparation and
coating application. Submit evidence that key personnel have successfully
performed surface preparation and application of tank linings in welded
petroleum storage tanks on a minimum of three separate projects within the
past three years. List information by individual and include the following:
a.
Name of individual and proposed position for this work.
b.
Information about each previous assignment in a welded petroleum
storage tank including:
Position or responsibility
Employer (if other than the Contractor)
Name of tank owner
Mailing address, telephone number, and telex number (if
non-US) of tank owner
Name of individual in tank owner's organization who can be
contacted as a reference
Location, size and description of tank
Dates work was carried out
Description of work carried out in tank
][1.4.3.6
Qualifications of Coating Manufacturer's Representative
**************************************************************************
NOTE: The inclusion of a manufacturers
representative in the pre-application meeting is
encouraged and is considered justified for large
projects. For smaller projects, the NACE inspector
can interface with the manufacturer for required
information and guidance.
**************************************************************************
Evidence of experience and training of the Coating Manufacturer's
Representative(s) shall include literature documenting name, phone number
and address, a statement from the coating manufacturer certifying that the
representative has successfully completed all of the manufacturer's
been directly involved in evaluation and application of industrial coatings
on a minimum of 10 steel structures within the last 5 years, and is not an
employee of the Contractor. The manufacturer's representative shall advise
on surface preparation, inspections, surface repair materials and methods,
material handling, batching and mixing, application, curing, and testing.
]1.4.3.7
Roof Joint Sealant Materials
Provide manufacturer's certification of conformance to contract
requirements.
SECTION 09973