Management System (RMS) are: "AE" for
Architect-Engineer; "DO" for District Office
(Engineering Division or other organization in the
District Office); "AO" for Area Office; "RO" for
Resident Office; and "PO" for Project Office. Codes
following the "G" typically are not used for Navy
projects.
Submittal items not designated with a "G" are
considered as being for information only for Army
projects and for Contractor Quality Control approval
for Navy projects.
**************************************************************************
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are [for Contractor Quality Control
approval.][for information only. When used, a designation following the
"G" designation identifies the office that will review the submittal for
the Government.] The following shall be submitted in accordance with
Section 01330 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Shop Drawings[; G][; G, [_____]]
Drawings showing fabrication details, materials, dimensions,
installation methods, anchors, and relationship to adjacent
construction.
SD-03 Product Data
Skylights
Manufacturer's descriptive data and catalog cuts.
Warranty
Manufacturer's 5 year complete warranty.
SD-06 Test Reports
Test Reports[; G][; G, [_____]]
Certified test reports from independent testing laboratory for
each type and class of panel system. Reports shall verify that
the material meets apecified performance requirements. Previously
completed test reports will be acceptable if they are current and
indicative of products used on this project. Where a Class A, B
or C roof is part of the project, a listing certificate for roof
covering systems category shall be provided certifying that the
product complies with the safety standards of ASTM E 108 and the
Uniform Building Code.
SD-07 Certificates
Skylights[; G][; G, [_____]]
Manufacturer's certificate stating that products meet or exceed
specified requirements. Skylight system shall be evaluated and
SECTION 08600
Page 6