ASTM E 331
(2000) Water Penetration of Exterior
Windows, Skylights, Doors, and Curtain
Walls by Uniform Static Air Pressure
Difference
ASTM E 72
(2004) Conducting Strength Tests of Panels
for Building Construction
ASTM E 84
(2004) Surface Burning Characteristics of
Building Materials
NATIONAL FENESTRATION RATING COUNCIL (NFRC)
NFRC 100
(2004) Procedure for Determining
Fenestration Product U-Factors
NFRC 200
(2004) Procedure for Determining
Fenestration Product Solar Heat Gain
Coefficient and Visible Transmittance
at
Normal Incidence
1.2
GENERAL REQUIREMENTS
The Contractor shall furnish and install commercially available [roof
windows] [unit skylights [flat glass] [domed] [pyramidal] [vaulted]] [metal
or wood framed skylights] which satisfy all requirements contained in this
section and have been verified by load testing and independent design
Contractor shall provide environmentally preferable products and work
practices, applicable to skylights, considering raw materials acquisition,
production, manufacturing, packaging, distribution, reuse, operation,
maintenance, and/or disposal of the products or services used in the
skylights. The skylight system shall be UV-stabilized, shatter proof and
energy efficient. The plastics used in the manufacture of the skylights
shall be light transmitting plastics for daylighting applications.
1.3
SUBMITTALS
**************************************************************************
NOTE: Submittals must be limited to those necessary
for adequate quality control. The importance of an
item in the project should be one of the primary
factors in determining if a submittal for the item
should be required.
A "G" following a submittal item indicates that the
submittal requires Government approval. Some
submittals are already marked with a "G". Only
delete an existing "G" if the submittal item is not
complex and can be reviewed through the Contractor's
submittal is sufficiently important or complex in
context of the project.
For submittals requiring Government approval on Army
projects, a code of up to three characters within
the submittal tags may be used following the "G"
designation to indicate the approving authority.
Codes for Army projects using the Resident
SECTION 08600