the operating sash of the storm window shall be in the same position as the
prime window.
2.3
**************************************************************************
NOTE: For most applications, the finish should be
clear anodized, Architectural Class II, or baked
enamel, at the option of the Contractor. Specify
other finish or color only if specific conditions
justify the additional cost or if required to match
finish on prime windows. Mill finish is not
recommended.
**************************************************************************
Exposed aluminum surfaces shall be factory finished with anodic coating or
organic coating. New storm windows shall have the same finish.
2.3.1
Anodic Coating
Exposed surfaces of aluminum extrusions and sheet shall be cleaned and
given an anodized finish conforming to AA DAF-45. Finish shall be [clear
(natural), designation AA-M10-C22-A31, Architectural Class II, AAMA 611]
[integral color anodized, designation AA-M10-C22-A32, Architectural Class
II, AAMA 611, or electrolytically deposited color anodized, designation
AA-M10-C22-A34, Architectural Class II, AAMA 611. Color shall be [as
indicated] [_____]].
2.3.2
Organic Coating
Exposed surfaces of aluminum extrusions and sheet shall be cleaned, primed,
and given a baked enamel finish in accordance with AAMA 2603, with total
dry film thickness not less than 0.02 mm 0.8 mil. The finish color shall
be [white] [as indicated] [_____].
PART 3
EXECUTION
3.1
PREPARATION
**************************************************************************
NOTE: Insert additional subparagraphs on repairing,
freeing stuck sash, weatherstripping, recalking,
reputtying, sanding, and painting to suit the
project. If other surfaces are to be painted, the
reputtying, sanding, and painting should be
specified in Section 09900, "Paints and Coatings."
**************************************************************************
Clean, repair, and paint existing prime windows which are to receive storm
windows before storm windows are installed. [Examination and repair of
weatherstripping and sealant of the prime window is not required.] Clean
glass [, wood,] and metal surfaces which will be between the storm and
prime windows with appropriate detergents or cleaning agents. Leave free
of dirt, streaks, fingerprints, and other soil.
3.2
INSTALLATION
Install square, in true plane, level, plumb, in alignment with adjacent
construction, and in accordance with manufacturer's printed instructions to
SECTION 08582
Page 6