projects, a code of up to three characters within
the submittal tags may be used following the "G"
designation to indicate the approving authority.
Codes for Army projects using the Resident
Management System (RMS) are: "AE" for
Architect-Engineer; "DO" for District Office
(Engineering Division or other organization in the
District Office); "AO" for Area Office; "RO" for
Resident Office; and "PO" for Project Office. Codes
following the "G" typically are not used for Navy
projects.
Submittal items not designated with a "G" are
considered as being for information only for Army
projects and for Contractor Quality Control approval
for Navy projects.
**************************************************************************
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are [for Contractor Quality Control
approval.][for information only. When used, a designation following the
"G" designation identifies the office that will review the submittal for
the Government.] The following shall be submitted in accordance with
Section 01330 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Wood windows; G, [_____]
Indicate elevations of units, full-size sections, fastenings,
methods of installation and anchorage, method of glazing,
locations of operating hardware, mullion details, method and
material for weatherstripping, [bar and muntin layouts,] method of
attaching [insect screens] [storm windows], details of
installation, and connections with other work.
SD-03 Product Data
Wood windows; G, [_____]
SD-08 Manufacturer's Instructions
Wood windows
Submit manufacturer's written instructions for installation.
SD-10 Operation and Maintenance Data
Wood windows, Data Package 1; G, [_____]
Submit data package in accordance with Section 01781 OPERATION
AND MAINTENCNE DATA.
1.3
DELIVERY AND STORAGE
Deliver windows to site in sealed undamaged cartons or in palletized
multiple units. Protect from damage, dampness and extreme temperature or
humidity changes. Store under cover in well-ventilated enclosed space. Do
not store in a building under construction until concrete, masonry, and