the Government.] The following shall be submitted in accordance with
Section 01330 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Hangar doors; G, [_____]
Submit the door manufacturer's complete schematic wiring
drawing showing the location of controls with the runs of conduit,
size of conduit, number and size of wires in each conduit,
location of junction boxes, and full details of control mountings.
Submit drawings showing details of construction, installation,
and operation; size, shapes, and thickness of materials; joints
and connections; reinforcing; hardware; mechanical devices;
electrical devices; and design and detail data for work of other
trades affected by hangar doors.
SD-05 Design Data
Hangar doors; G, [_____]
Submit design drawings and structural, mechanical, and "U" value
calculations.
SD-10 Operation and Maintenance Data
Hangar doors, Data Package 2; G, [_____]
Submit in accordance with Section 01781 OPERATION AND
MAINTENANCE DATA. Include wiring and control diagrams.
1.4
QUALITY ASSURANCE
1.4.1
Manufacturer's Qualifications
The hangar door manufacturer shall be one who is regularly engaged in the
production of steel sliding hangar doors of type and size required for this
project.
1.4.2
Installer's Qualifications
The installation supervisor shall be an authorized representative of the
door manufacturer. Mechanics shall be skilled and experienced in the
erection of hangar doors of type and size required for this project.
1.5
DELIVERY, STORAGE, AND HANDLING
Deliver materials which are not shop installed on the doors in original
rolls, packages, containers, boxes, or crates bearing the manufacturer's
name, brand, and model number. Store materials and equipment in dry
locations with adequate ventilation, free from dust and water, and so as to
permit access for inspection and handling. Handle doors carefully to
prevent damage. Remove damaged items that cannot be restored to like-new
condition and provide new items.
SECTION 08342