Storm doors]
[
Submit one complete door unit of each type for approval. Label
the sample for identification and, if approved, forward to the
site. Samples in good condition may be installed if clearly
identified and the locations are recorded. Do not remove
identification and approval marks until final acceptance.]
[
Submit one full-sized corner at least 150 mm 6 inches long and
75 mm 3 inches wide; show construction of each type frame.]
Submit for approval color range samples for color finishes.
The
actual finish shall be within the range represented by the
approved samples.
SD-06 Test Reports
Storm doors
Submit test reports indicating that storm doors conform to
applicable requirements of AAMA 1102.7 and requirements specified
herein.
SD-10 Operation and Maintenance Data
Storm doors, Data Package 1; G, [_____]
Submit operation and maintenance data in accordance with Section
01781 OPERATION AND MAINTENANCE DATA.
1.3
DELIVERY, STORAGE, AND HANDLING
Carefully pack products
in poly bags or other protective containers.
Deliver products to the
project site in undamaged condition, store out of
contact with the ground
under weathertight covering, and protect against
damage. Do not install
damaged units. Replace damaged units with new
units.
PART 2
PRODUCTS
2.1
MATERIALS
Metal storm doors shall be either aluminum or steel.
2.1.1
Wrought Aluminum, Sheet or Plate
ASTM B 209MASTM B 209, Alloy 3000 or 5000 series.
2.1.2
Extruded Aluminum
ASTM B 221MASTM B 221, Alloy 6063 or 6463, Temper T5 or T6.
2.1.3
Steel
Sections of the door shall be of roll formed tubular lock seam
SECTION 08181
Page 6