NOTE: Modify paragraph to indicate where weather
stripping is required. If weather stripping is not
required, delete paragraph.
**************************************************************************
Provide on head, jamb, and sills of [exterior doors] [interior doors
[_____]]. [Form of 1.5 mm 1/16 inch thick fabric-reinforced neoprene.
Install using steel continuous retainers.] [Provide nylon filament brush
type in extruded aluminum retainers.]
2.5.4
Locking Device
**************************************************************************
of required exitways unless approval is obtained
from the Fire Protection Engineer.
**************************************************************************
[Provide heavy-duty hasp and staple on doors [_____]. Locate on [_____]
side.] [Provide heavy-duty mortise sliding door locks with [double]
[single] pin-tumbler cylinders.]
2.6
FINISH
2.6.1
Exterior Door[s] [and Interior Door[s]] With Hardware
Steel Surfaces of Exterior Door[s] [and Interior Door[s]] Including
Hardware: Concealed surfaces shall be provided with a galvanized finish.
Exposed surfaces shall be provided with a shop-primed galvanized finish.
Galvanizing shall conform to ASTM A 653/A 653M, coating designation Z275 G90
for steel sheets and ASTM A 123/A 123M for assembled steel products. All
galvanized surfaces damaged during fabrication shall be cleaned and coated
with galvanized repair paint. Prior to receiving primer, thoroughly clean
all surfaces and phosphate treat to assure maximum paint adherence. Primer
shall be a metallic oxide or synthetic resin primer of the manufacturer's
standard type and shall be applied by dipping or spraying.
2.6.2
Steel Surfaces of Interior Door[s] Including Hardware
**************************************************************************
NOTE: Delete paragraph if interior doors are to
receive same finish as exterior doors.
**************************************************************************
Exposed surfaces shall be provided with a shop-primed finish or a
galvanized finish. Galvanizing shall conform to ASTM A 653/A 653M, coating
designation Z275 G90 for steel sheets and ASTM A 123/A 123Mfor assembled
steel products. Primer shall be a metallic oxide or synthetic resin primer
of the manufacturer's standard type and shall be applied by dipping or
spraying. Prior to receiving primer, thoroughly clean all surfaces and
phosphate treat to assure maximum paint adherence.
2.7
LABELS
Fire doors shall bear labels of the UL or FM P7825 as evidence of the
door[s] conforming to the rating[s] indicated. The construction details
necessary to obtain the labels shall take precedence over details indicated
or specified herein. Labels shall be a minimum of 20 by 50 mm 3/4 by 2 inch
SECTION 08162
Page 11