[Show a complete description of the procedures for the
installation of each phase of the system indicating the type of
materials, thicknesses, identity codes, sequence of laying
insulation, location of ridges and valleys, special methods for
cutting and fitting of insulation, and special precautions. The
SD-03 Product Data
[Fasteners] [Asphalt]; G
Insulation; G
**************************************************************************
NOTE: Insulation may be specified solely for use on
steel decks as underlayment for roofing when
insulation is not required for thermal properties.
FM Approval Guide includes requirements for
fasteners for 1-60 or 1-90 classifications or
resistance to wind uplift pressures of 2.87 or 4.31
kPa 60 or 90 psf, respectively. Refer to
MIL-HDBK-1002/2, for wind loads. Refer to FM Loss
Prevention Data Sheet 1-7 for wind uplift prevention
design. Specify no less than 4.31 kPa 90 psf for
roofs located in coastal areas. Specify other
fastener requirements if 1-90 standards are
determined to be inadequate.
**************************************************************************
[Include minimum thickness of insulation for steel and concrete
decks and fastener pattern for insulation on steel decks.]
SD-06 Test Reports
Flame spread and smoke developed ratings
Submit in accordance with ASTM E 84.
SD-07 Certificates
**************************************************************************
NOTE: Include these requirements when tapered
insulation is to be used.
**************************************************************************
Installer qualifications
SD-08 Manufacturer's Instructions
Roof insulation, including field of roof and perimeter attachment
requirements.
1.3
MANUFACTURER'S CERTIFICATE
Submit certificate from the insulation manufacturer attesting that the
installer has the proper qualifications for installing tapered roof
insulation systems.
SECTION 07220
Page 7