materials in accordance with manufacturer's instructions, and use within
to special precautions of the manufacturer, unless precautions conflict
with local, state, and federal regulations. Promptly remove from the site
materials or incomplete work adversely affected by exposure to moisture or
freezing. Store materials on pallets and cover from top to bottom with
canvas tarpaulins.
1.5
ENVIRONMENTAL CONDITIONS
Apply materials when ambient temperature is 4 degrees C 40 degrees F or
above for a period of 24 hours prior to the application and when there is
no ice, frost, surface moisture, or visible dampness on the substrate
surface. Apply materials when air temperature is expected to remain above 4
degrees C 40 degrees F during the cure period recommended by the
manufacturer. Moisture test for substrate is specified under paragraph
entitled "Moisture Test." Work may be performed within heated enclosures,
provided the surface temperature of the substrate is maintained at a
minimum of 4 degrees C 40 degrees F for 24 hours prior to the application
of the waterproofing, and remains above that temperature during the cure
period recommended by the manufacturer.
PART 2
PRODUCTS
2.1
FLUID-APPLIED MEMBRANE
**************************************************************************
NOTE: ASTM C 836 is a materials performance
specification; it does not specify any particular
elastomer or elastomeric-extender combination.
**************************************************************************
ASTM C 836.
2.2
MEMBRANE PRIMER
As recommended by the fluid-applied membrane manufacturer unless
specifically prohibited by the manufacturer of the fluid-applied membrane.
2.3
SEALANT
**************************************************************************
NOTE: Specify sealant conforming to FS TT-S-227 or
FS TT-S-230 in Section 07920, "Joint Sealants." If
no such section is required, specify sealant in this
section.
**************************************************************************
As specified in Section 07920 JOINT SEALANTS.
2.4
SEALANT PRIMER
As specified in Section 07920 JOINT SEALANTS.
2.5
BACKING MATERIAL
**************************************************************************
NOTE: Include the following paragraph in Section
07920, "Joint Sealants":
SECTION 07141
Page 7