1. Slope: Provide slope toward drains (after
deflections due to applied load and creep) of not
less than one percent 10 millimeters (mm) per meter
1/8 inch per foot.
2. Wall Flashing: Extend wall flashing to at least
100 mm 4 inches above wearing surface and higher
where exposure is more severe. If top of flashing
is recessed under a concrete wall, counterflashing
is not necessary. Metal counterflashing is
necessary at masonry wall intersections. Flash
right-angle intersection of deck and wall with an
elastomeric sheet.
**************************************************************************
**************************************************************************
NOTE:
This section contains both metric and
inch-pound graphics.
NUMBER
TITLE
1
Basic Components of Membrane with Separate Wearing Course
2
Flashing at Cracks and Nonmoving Joints in the Concrete
3
Expansion Joint Flashing
4
Expansion Joint Flashing at Wall
5
Terminal Condition with Masonry Above Finish Wearing Surface
at Grade
6
Wall Flashing on Concrete Wall
7
Wall - Deck Flashing
8
Penetration Flashing
9
Drain Flashing
DO NOT INCLUDE THE SKETCHES OR LIST OF SKETCHES IN
THE PROJECT SPECIFICATIONS. USE SKETCHES FOR
PREPARING DETAILS ON THE DRAWINGS.
**************************************************************************
**************************************************************************
NOTE: TO DOWNLOAD UFGS GRAPHICS
Go to http://www.ccb.org/docs/ufgshome/graphtoc.pdf.
**************************************************************************
PART 1
GENERAL
1.1
REFERENCES
**************************************************************************
NOTE: Issue (date) of references included in
provided by the latest guide specification. Use of
SpecsIntact automated reference checking is
recommended for projects based on older guide
specifications.
**************************************************************************
The publications listed below form a part of this specification to the
extent referenced. The publications are referred to within the text by the
basic designation only.
SECTION 07141
Page 4