fabricated of [[0.75] [_____] mm [0.0295] [_____] inch design thickness or
thicker steel] [the steel design thickness required by the design drawings]
and shall be [shop painted] [galvanized] [painted with an epoxy coating or
equivalent applied to prime-coating in accordance with manufacturer's
standard] [zinc-coated in conformance with ASTM A 653/A 653M, G90 coating
class or aluminum-zinc coated in accordance with ASTM A 792/A 792M Coating
Designation AZ55].
2.3.3
Form Deck
Deck used as formwork for concrete shall conform to ASTM A 653/A 653M or
ASTM A 1008. Form deck shall be fabricated of[ [0.38] [____] mm [0.015]
[____] inch design thickness or thicker steel.] [the steel design thickness
required by the design drawings.] [Paint with one coat of manufacture's
standard paint.]
[Zinc-coat in conformance with ASTM A 653/A 653M,[ G60][
G90] coating class.]
2.3.4
Composite Deck
[ Composite deck assembly shall conform to ASTM A 653/A 653M or ASTM A 1008/A
1008M. Deck used as the tension reinforcing in composite deck shall be
fabricated if [0.75][____] mm[0.0295] [____] inch design thickness or
thicker steel.] [The steel design thickness required by the design
drawings. Zinc-coat in conformance with ASTM A 653/A 653M, [G60][G90]
coating class.
In addition to resisting shear, devices shall provide resistance to
vertical separation between the steel deck and the concrete. Provide one
of the following types of shear devices:
a.
Mechanically fixed shear devices such as embossments, holes, or
welded buttons.
b.
Mechanically fixed shear devices such as inverted,
triangular-shaped ribs.
][2.3.5
Cellular Decking
Cellular decking provided as wire raceways, shall conform to NFPA 70.
][2.3.6
Acoustical Steel Deck
**************************************************************************
commonly used coefficient. The coefficient can also
be obtained from manufacturer's literature.
considered and the appropriate value inserted. The
manufacturer's standard acoustical steel deck shall
be provided where indicated.
**************************************************************************
[_____], when tested in accordance with ASTM C 423, Standard Mounting No.
6. Sound absorbing materials shall be either [glass fiber in roll or
premolded form for acoustical steel deck (noncellular)] [and] [or] [glass
fiber rigid strip for acoustical steel deck (cellular)] in accordance with
manufacturer's standards. The Contractor shall comply with EPA
SECTION 05310