SSPC Paint 25
(1997; R 2000) Zinc Oxide, Alkyd, Linseed
Oil Primer for Use Over Hand Cleaned
Steel, Type I and Type II
SSPC SP 3
(1982; R 2000) Power Tool Cleaning
SSPC SP 6
(2000) Commercial Blast Cleaning
1.2
SYSTEM DESCRIPTION
**************************************************************************
NOTE: Consult with the structural designer. Use
AISC 316 and AISC 317 when allowable stress is used
for design, and use the AISC 325 when the load and
designers are using AISC 316 and AISC 317.
**************************************************************************
**************************************************************************
NOTE: The design should be checked to ensure that
adequate supports at appropriate spacings have been
provided for the installation of piping, expansion
tanks, unit heaters, suspended ceilings and similar
items.
Provisions for using self-locking nuts should be
considered where shock or vibration would be a
problem.
**************************************************************************
Provide the structural steel system, including [shop primer] [galvanizing],
complete and ready for use. Structural steel systems including design,
materials, installation, workmanship, fabrication, assembly, erection,
inspection, quality control, and testing shall be provided in accordance
with [AISC 316 and AISC 317] [AISC 325] except as modified in this contract.
1.3
MODIFICATIONS TO REFERENCES
**************************************************************************
NOTE: Use the first paragraph when AISC 316 and
AISC 317 (allowable stress) is used for design, and
use the second paragraph when AISC 325 (load and
**************************************************************************
[In [AISC 316, AISC 317, AISC 335, AISC 303, AISC 348, and AISC S340,
except as modified in this section, shall be considered a part of AISC 316
and AISC 317 and is referred to in this section as AISC 316 and AISC 317.]]
[In [AISC 325, AISC 350, AISC 303, AISC 348, and AISC S340, except as
modified in this section, shall be considered a part of AISC M018L and AISC
M019L and is referred to in this section as AISC 325.]]
1.4
SUBMITTALS
**************************************************************************
NOTE: Submittals must be limited to those necessary
for adequate quality control. The importance of an
SECTION 05120
Page 9