TABLE II
TOLERANCES
Variation from the plumb in the lines
and surfaces of columns, walls and arises
____________________________________________________________
In
adjacent masonry units
3
mm
In
3m
6
mm
In
6m
10
mm
In
12 m or more
13
mm
Variations from the plumb for external corners,
expansion joints, and other conspicuous lines
____________________________________________________________
In 6 m
6 mm
In 12 m or more
13 mm
Variations from the level for exposed lintels,
sills, parapets, horizontal grooves, and other
conspicuous lines
____________________________________________________________
In 6 m
6 mm
In 12 m or more
13 mm
Variation from level for bed joints and top
surfaces of bearing walls
____________________________________________________________
In 3 m
6 mm
In 12 m or more
13 mm
Variations from horizontal lines
____________________________________________________________
In 3 m
6 mm
In 6 m
10 mm
In 12 m or more
13 mm
Variations in cross sectional dimensions of
columns and in thickness of walls
____________________________________________________________
Minus
6 mm
Plus
13 mm