Field Testing
Test reports in booklet form showing all field tests, including
component adjustments and demonstration of compliance with the
specified performance criteria, upon completion and testing of the
installed system. Each test report shall indicate the final
position of controls.
SD-10 Operation and Maintenance Data
Vehicle Barriers[; G][; G, [_____]]
Operating and Maintenance Instructions
Data Package 4 in accordance with Section 01781 OPERATION AND
MAINTENANCE DATA.
minimum of 2 weeks prior to field training. One complete set
Manuals shall be approved prior to acceptance. Operation manuals
shall outline the step-by-step procedures required for system
startup, operation, and shutdown. The manuals shall include the
manufacturer's name, model number, service manual, parts list, and
brief description of all equipment and their basic operating
procedures, possible breakdowns and repairs, and troubleshooting
guide. The manuals shall include piping layout, equipment layout,
and simplified wiring and control diagrams of the system as
installed. The manuals shall also include synthetic biodegradable
hydraulic oil types to be used for ambient temperature ranges of
minus 34 degrees C minus 30 degrees F to plus 66 degrees C 150
degrees F to cover winter operation, summer operation, and ambient
temperature ranges in between.
1.3
GENERAL REQUIREMENTS
**************************************************************************
NOTE: Performance levels are based on the following:
1. The Department of State (DOS) publication
SD-SDT-02.01 Specification for Vehicle Crash Testing
of Perimeter Barriers and Gates (April 1985) in
which:
Impact Conditions are:
Condition
Vehicle
Impact
Kinetic
Designation
Weight
Speed
Energy
K4
6,800
kg
48
km/h
610 kJ
(15,000
lb)
(30
mph)
(450,000 ft-lb)
K8
6,800
kg
65
km/h
1084 kJ
(15,000
lb)
(40
mph)
(800,000 ft-lb)
K12
6,800
kg
80
km/h
1695 kJ
(15,000
lb)
(50
mph)
(1,250,000 ft-lb)
Performance Levels are:
SECTION 02840