Submittal items not designated with a "G" are
considered as being for information only for Army
projects and for Contractor Quality Control approval
for Navy projects.
**************************************************************************
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are [for Contractor Quality Control
approval.][for information only. When used, a designation following the
"G" designation identifies the office that will review the submittal for
the Government.] The following shall be submitted in accordance with
Section 01330 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Speed Reducers[; G][; G, [_____]]
Lubrication System[; G][; G, [_____]]
consisting of a complete list of equipment and materials,
including manufacturer's descriptive and technical literature;
performance charts and curves; catalog cuts; and installation
instructions. Drawings shall show proposed layout and anchorage
of equipment and appurtenances, and equipment relationship to
other parts of work including clearances for maintenance and
operation.
SD-03 Product Data
System Description[; G][; G, [_____]]
Shafts[; G][; G, [_____]]
[Couplings] [Universal Joints][; G][; G, [_____]]
Backstop[; G][; G, [_____]]
Housing[; G][; G, [_____]]
Lubrication System[; G][; G, [_____]]
Speed Reducers[; G][; G, [_____]]
Lubricant[; G][; G, [_____]]
SD-06 Test Reports
Shop Testing[; G][; G, [_____]]
A shop test report fully documenting the test.
Field Testing[; G][; G, [_____]]
A field test report documenting all data for load and speed
measurement, lubrication oil temperature and flow, cooling water
temperature and flow, gear contact patterns, adjustment of
component settings, and otherwise showing compliance with
specified performance criteria.
SD-10 Operation and Maintenance Data
SECTION 15005A
Page 6