2.5.2
Provide [each] elevator with two-way, automatic self-leveling device that
brings car floor to within 6 mm 1/4 inch of level with floor landing
regardless of load, position of hoistway door, or direction of travel.
2.6
2.6.1
Capacity and Data Plates
Attach faceplates with spanner security screws. On car panel, provide
stainless steel capacity and data plates, with name of elevator
manufacturer.
2.6.2
Car and Hall Buttons
Provide recessed tamper-proof push buttons of minimum 20 mm 3/4 inch size
satin-finish stainless steel, with illuminating jewel center.
2.6.3
Hall Station Door Operating Buttons
**************************************************************************
NOTE: Use this paragraph for freight elevators with
power-operated bi-parting doors. The number and
size of hall car stations will be indicated on the
drawings.
**************************************************************************
Identical in size and design to hall call buttons, but not illuminating.
2.6.4
**************************************************************************
NOTE: Use two panels for busy passenger elevators
in hospital buildings and office buildings. Use one
car operating panel for single or two elevator
system where traffic is moderate such as in
barracks, warehouses, clinics or shops. For front
and rear openings at a floor, provide two floor
buttons marked "F" and "R" for operating door open
and close.
**************************************************************************
Provide each car with [one] [two] car operating panel that contains
operation controls and communication devices. Provide exposed, flush
mounted buttons for the controls that must be passenger accessible.
Provide service cabinet or keyed switches for those switches that should
not be passenger accessible. Allow maximum 1200 mm 48 inch height between
car floor and center line of top operating buttons. Allow 900 mm 35 inch
height between car floor and center line of bottom button. Use engraving
and backfilling or photo etching for button and switch designations. Do
not use attached signs.
2.7
PASSENGER CONTROLS
2.7.1
**************************************************************************
SECTION 14240