lead-based paint/paint with lead removal/control plan including CP
approval (signature, date, and certification number); G
Rental equipment notification; G
Respiratory Protection Program; G
Hazard Communication Program; G
[EPA] [or] [State] approved hazardous waste treatment, storage, or
disposal facility for lead disposal; G
Lead Waste Management Plan; G
Vacuum filters; G
[
Clearance Certification; G]
SD-08 Manufacturer's Instructions
Chemicals and equipment; G
Materials; G
SD-11 Closeout Submittals
Completed and signed hazardous waste manifest from treatment or
disposal facility; G
Certification of Medical Examinations; G
Employee Training Certification; G
[
Waste turn-in documents or weight tickets for non-hazardous wastes
that are disposed of at sanitary or construction and demolition
landfills; G]
1.5
QUALITY ASSURANCE
1.5.1
Qualifications
1.5.1.1
Qualifications of CP
Submit name, address, and telephone number of the CP selected to perform
responsibilities specified in paragraph entitled "Competent Person (CP)
Responsibilities." Provide previous experience of the CP. Submit proper
documentation that the CP is trained [and licensed] [and certified] in
accordance with Federal, State, and local laws.
1.5.1.2
Training Certification
**************************************************************************
NOTE: State or local regulations may consider
LBP/PWL removal/control work as "lead-based paint
hazard reduction activities" or "deleading." The
SECTION 13283N
Page 11