DETAIL SHEET 10. The glovebag assembly shall be 0.15 mm 6 mil thick
plastic, prefabricated and seamless at the bottom with preprinted OSHA
warning label.
1.23.2
Duct Tape
Industrial grade duct tape of appropriate widths suitable for bonding sheet
plastic and disposal container.
1.23.3
Disposal Containers
**************************************************************************
NOTE: Consult customer, federal, state, and local
requirements for the type of disposal container
allowed.
**************************************************************************
Leak-tight (defined as solids, liquids, or dust that cannot escape or spill
out) disposal containers shall be provided for ACM wastes as required by 29
CFR 1926.1101 and DETAIL SHEETS 9A, 9B, 9C and 14. Disposal containers can
be in the form of:
a.
Disposal Bags
b.
Fiberboard Drums
c.
Cardboard Boxes
1.23.4
Sheet Plastic
**************************************************************************
NOTE: Consult customer, federal, state and local
requirements. If necessary, specify the type of
sheet to be used and select the color and surface
treatment.
**************************************************************************
Sheet plastic shall be polyethylene of 0.15 mm 6 mil minimum thickness and
shall be provided in the largest sheet size necessary to minimize seams ,[as
[black] and conform to ASTM D 4397, except as specified below:
1.23.4.1
Flame Resistant
Where a potential for fire exists, flame-resistant sheets shall be
provided. Film shall be [frosted] [or] [black] and shall conform to the
requirements of NFPA 701.
1.23.4.2
Reinforced
Reinforced sheets shall be provided where high skin strength is required,
such as where it constitutes the only barrier between the regulated area
and the outdoor environment. The sheet stock shall consist of translucent,
nylon-reinforced or woven-polyethylene thread laminated between 2 layers of
polyethylene film. Film shall meet flame resistant standards of NFPA 701.
1.23.5
Mastic Removing Solvent
Mastic removing solvent shall be nonflammable and shall not contain
SECTION 13280A