[2.3.17
Doors and Windows
**************************************************************************
NOTE: Normally, doors and windows should be
specified in separate sections to assure proper
coordination with doors, windows, glass, and
hardware which are part of the project occurring in
other types of construction in the project, and to
allow the Contractor to obtain competitive pricing.
If the project involves only small storage type
buildings with no other type of building
construction, and building manufacturer's standard
doors and windows will be satisfactory, the doors,
windows, glazing, and hardware, if necessary, may be
included in this section.
**************************************************************************
**************************************************************************
NOTE: Insert appropriate Section numbers and titles
in blankS below using format per UFC 1-300-02.
**************************************************************************
Doors and windows are specified in [_____] and [_____]. Provide framing
members and flashings as necessary for installation of the doors and
windows.
2.3.17.1
Swinging Personnel Doors and Frames
SDI A250.8, Grade II, Model 1, 2, 3, or 4, design as indicated, zinc-coated
and shop primed, exterior mounting.[ Doors shall be glazed with [_____]
glass.][ Hardware is specified in Section 08710 DOOR HARDWARE.][ Hardware
shall conform to BHMA A156.1, BHMA A156.2, BHMA A156.3, and BHMA A156.4.]
Doors shall be provided with the following hardware:
DOOR NO.
HARDWARE REQUIRED
[_____]
[_____]
2.3.17.2
Sliding Doors
[Hollow metal][Sheet metal] type. [Hollow metal type shall conform to SDI
A250.8, Grade II, Model 1, 2, 3, or 4, design as indicated, zinc-coated and
shop primed.][Sheet metal type shall consist of steel framework covered
with siding of the same type and finish as used for the building.] Provide
hardware necessary for the complete installation of sliding doors. Sliding
door hardware shall include heavy-duty zinc-coated steel tracks, brackets,
end and center stops, not less than two-wheel ball or roller bearing,
adjustable type hangers - two per leaf, binders, guides, handles, heavy
type cane bolt and socket for one leaf of pairs of doors, padlock eyes or
heavy safety hasp, and flashing for outside door tracks. Hardware items
shall be approved types, standard with the door manufacturer.
2.3.17.3
Overhead Doors Rolling Doors
**************************************************************************
NOTE: Insert appropriate Section number and title
in blank below using format per UFC 1-300-02.
**************************************************************************
SECTION 13120
Page 33