Overhead rolling doors shall conform to the requirements of [Section 08330
OVERHEAD ROLLING DOORS][_____]. Hardware shall be [as scheduled [herein]
[on the drawings]] [as specified in Section 08710 DOOR HARDWARE].
2.3.17.4
Sectional Overhead Doors
Sectional overhead doors shall conform to the requirements of Section 08361
SECTIONAL OVERHEAD DOORS. Hardware shall be [as scheduled [herein] [on the
drawings]] [as specified in Section 08710 DOOR HARDWARE].
2.3.17.5
Vertical Lift Doors
Vertical lift doors shall conform to the requirements of Section 08370
VERTICAL LIFT DOORS. Hardware shall be [as scheduled [herein] [on the
drawings]] [as specified in Section 08710 DOOR HARDWARE].
2.3.17.6
[Aluminum Windows] [or] [Steel Windows]
**************************************************************************
NOTE: Choose "a. Aluminum Windows" or "b. Steel
Windows" or choose both leaving the Contractor the
option. Steel windows are no longer completely
American made. Contact the Contract Office for a
waiver.
**************************************************************************
[
[a.
Aluminum Windows:] AAMA 101, Type [A-C] [HS-C] [HS-HC] [C-C]
[C-HC] [DH-C] [DH-HC] [P-C] [P-HC]. Windows shall be factory
glazed with [_____] glass. Provide aluminum with [an
AA-M10-C22-A31 clear anodized finish in accordance with the
requirements of AA 45] [manufacturer's standard factory finish,
color as indicated] [the same finish specified in paragraph
entitled "Finish," color as indicated]. Ventilating sections shall
be provided with insect screens. [Windows shall be provided with
thermal barrier features.]]
[
[b.
Steel Windows:] SWI SGSW, [commercial projected] [architectural
projected] [standard intermediate projected] [standard
intermediate casement] type. Provide [manufacturer's standard
factory finish, color as indicated] [the same finish specified in
paragraph entitled "Finish," color as indicated]. Provide
ventilating sections with insect screens. Provide factory glazed
windows with [_____] glass. [Provide windows with thermal barrier
features.]]
]2.3.18
Of same materials and finish as the building.
Soffit materials shall be
[_____] [of material indicated].
2.3.19
Sealant
Sealant shall be an elastomeric type containing no oil or asphalt. Exposed
sealant shall be [colored to match the applicable building color] [clear]
and shall cure to a rubber like consistency.
SECTION 13120
Page 34