Five-digit designations refer to FED-STD-595.
2.2.1
Exposed Surfaces
Exterior of doors and exposed surfaces of cabinet body shall be decorative
laminated plastic of color and pattern [indicated] [specified].
2.2.2
Concealed Surfaces
Interior of doors and cabinet body, and concealed exterior surfaces of
cabinet body, shall be nondecorative laminated plastic.
2.3
END CURBS
**************************************************************************
NOTE: Delete this paragraph if end curbs are not
required.
**************************************************************************
Provide end curbs to match back splash where end of countertop abuts a wall.
2.4
DRAWERS
**************************************************************************
NOTE: Delete this paragraph if drawers are not
required.
**************************************************************************
Where drawers are indicated in vanities, comply with FS A-A-50565 for
drawers, drawer slides, and slide supports.
2.5
SOURCE QUALITY CONTROL
Sampling and Examination:
FS A-A-50567.
PART 3
EXECUTION
3.1
INSTALLATION
3.1.1
Final Assembly
Distribute vanities to rooms [as indicated] [as directed]. Uncrate,
assemble, adjust as necessary, and place as specified or indicated,
complete with accessories and hardware. Position vanities [as indicated]
[as directed].
3.1.2
Fastening
**************************************************************************
NOTE: Ensure that work referred to is actually
specified in the referenced sections.
**************************************************************************
Fasten wood vanities as specified in FS A-A-50567. Fasten steel vanities
through the holes in vanity back flanges. Fasteners shall be appropriate
for use with the wall construction. Seal joint between back splash and
wall and between end curb and wall as specified in Section 07920 JOINT
SECTION 12301N
Page 5