for Navy projects.
**************************************************************************
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are [for Contractor Quality Control
approval.][for information only. When used, a designation following the
"G" designation identifies the office that will review the submittal for
the Government.] The following shall be submitted in accordance with
Section 01330 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Vanities; [G]
Show configuration, materials, thicknesses, hardware, finishes,
and colors of vanities for the project.
1.3
DELIVERY, STORAGE, AND HANDLING
Deliver vanities undamaged and store in a safe, dry, and clean location.
Handle so as to prevent damage.
PART 2
PRODUCTS
2.1
VANITIES
**************************************************************************
NOTE: Insert type and size required. Sizes listed
are included in FS A-A-50567 and should be used
unless otherwise approved by the Engineering Field
Division Code 04 in writing. If other sizes are
required, determine whether modification of
door/intermediate panel configuration is required to
maintain proper door size and structural support.
**************************************************************************
FS A-A-50567, [Type I (single lavatory, double doors), Size [A (750 mm30
inches wide)] [B (900 mm36 inches wide)] [C (1050 mm42 inches wide)] [D (
1200 mm48 inches wide)]] [Type II (double lavatory, two sets of double
doors), Size A (1500 mm60 inches wide)] [Type [_____], except size shall be
[as indicated] [[_____] mm inches wide]], and except as specified herein.
Wood construction shall be used. Particleboard shall not be used.
Countertop, doors, and all wood panels shall be 20 mm 3/4 inch plywood, PS1,
Exterior Type, Grade A-A. Chromium-plated brass pulls or aluminum pulls
and chromium-plated, spring-loaded, self-closing, adjustable, European type
hinges may be used in lieu of pulls, hinges, and magnetic catches specified
in FS A-A-50567.
2.1.1
Quantity
[_____] [As indicated].
2.2
**************************************************************************
NOTE: Since a wood or steel constructed vanity is
the Contractor's option, specify finish, pattern,
and color for laminated plastic for both and a paint
color for steel.
SECTION 12301N
Page 4