accessories attached to the panels.
**************************************************************************
2.1
TOILET ENCLOSURES
Toilet enclosures shall conform to CID A-A-60003, Type I, Style [A, floor
supported] [B, ceiling hung] [C, overhead braced] [F, overhead
braced-alcove]. Width, length, and height of toilet enclosures shall be as
shown. Finish surface of panels shall be [painted metal, Finish 1]
[laminated plastic, Finish 3] [_____]. Panels indicated to receive toilet
paper holders or grab bars as specified in Section 10800 TOILET
ACCESSORIES, shall be reinforced for mounting of the items required. Grab
bars shall withstand a bending stress, shear stress, shear force, and a
tensile force induced by 1112 N 250 lbf. Grab bars shall not rotate within
their fittings.
2.2
ROOM ENTRANCE SCREENS
**************************************************************************
NOTE: Length and height of room entrance screens
will be shown on the drawings, using standard size
panels and pilasters to the maximum extent
practicable.
**************************************************************************
Room entrance screens shall conform to CID A-A-60003, Type II, Style [A,
floor supported] [E, wall hung] [_____]. Finish surface of screens shall
be [painted metal, Finish 1] [laminated plastic, Finish 3] [_____]. Length
and height of screens shall be as shown.
2.3
URINAL SCREENS
**************************************************************************
NOTE: Use of urinal screens between individual
urinals will be dependant on the function of the
facility. Use of urinal screens will normally be
limited to those applications where sanitary
protection is required, such as between a urinal and
an immediately adjacent lavatory. Style A screens
should normally be between 600 to 900 mm (24 to 36
in) wide. Style E screens should normally be
between 400 to 600 mm (18 to 24 in) wide. Wall
hung, Style E, urinal screens will be used only
where the supporting construction is masonry or
concrete. Where high use is expected, choose the
last bracketed sentence.
**************************************************************************
Urinal screens shall conform to CID A-A-60003, Type III, Style [A, floor
supported] [B, ceiling hung] [C, overhead braced] [D, floor to ceiling
hung] [E, floor to ceiling post supported]. Finish surface of screens
shall be [painted metal, Finish 1] [laminated plastic, Finish 3] [_____].
Width and height of urinal screens shall be as shown. Secure wall hung
urinal screens with [a minimum of three wall stirrup brackets.] [1050 mm 42
inch long, continuous flanges.]
2.4
HARDWARE
Hardware for the toilet partition system shall conform to CID A-A-60003 for
SECTION 10153
Page 6