NOTE: Include this paragraph only when access
panels are specified in paragraph titled SUSPENSION
SYSTEM. Delete identification code numbers and
systems not applicable to the particular project and
add additional numerical codes and system
descriptions if necessary. Code numbers and
corresponding system descriptions shall remain
unchanged, i.e., if "sprinkler system" is omitted,
the code number "6" will also be omitted from the
listing.
**************************************************************************
Access panels shall match adjacent acoustical units and shall be designed
and equipped with suitable framing and fastenings for removal and
replacement without damage. Panel shall be not less than 300 by 300 mm 12
by 12 inches or more than 300 by 600 mm. 12 by 24 inches.
a. An identification plate of 0.8 mm 0.032 inch thick aluminum, 19 mm
3/4 inch in diameter, stamped with the letters "AP" and finished the
same as the unit, shall be attached near one corner on the face of each
access panel.
b. Identify ceiling access panel by a number utilizing white
identification plates or plastic buttons with contrasting numerals.
The plates or buttons shall be of minimum 25 mm 1 inch diameter and
securely attached to one corner of each access unit. Provide a
typewritten card framed under glass listing the code identification
numbers and corresponding system descriptions listed above. Mount the
framed card where directed and furnish a duplicate card to the
Contracting Officer. Code identification system shall be as follows:
1
Fire detection/alarm system
2
3
Plumbing system
4
5
6
Sprinkler system
7
Intercommunication system
8
Nurse's call system
9
Pneumatic tube system
10
Medical piping system
11
Program entertainment
12
Telephone junction boxes
13
Detector X-ray
14
[_____]