devices to building structure and not to wall system. Place [concrete]
[mineral fiber] [_____] on [steel plates attached to bottom of floor slab]
[impaling chips embedded in edge of floor slab] [_____].
3.2.8
Field Applied Insulation
**************************************************************************
separate section for field applied insulation, add
here and delete cross-reference to other section.
Where field applied insulation is specified in
another section, keep cross-reference and coordinate
fire rating and U-value with the other section. See
rating requirements of insulation.
**************************************************************************
**************************************************************************
NOTE: Insert appropriate Section number and title
in blank below using format per UFC 1-300-02.
**************************************************************************
Provide insulation with minimum R-value of [_____], on clean, dry, properly
prepared surfaces of [masonry] [concrete] [_____] back-up wall in
accordance with [_____] INSULATION using approved accessories and methods
as recommended by insulation manufacturer unless indicated or specified
otherwise. Cover and protect each day's application until protection is
provided by completed work.
3.3
3.3.1
Galvanizing
Conform to ASTM A 123/A 123M, ASTM A 153/A 153M, and ASTM A 653/A 653M, as
applicable.
3.3.1.1
Repair of Zinc-Coated Surfaces
Repair zinc coated surfaces damaged by welding or other means with
galvanizing repair paint or by application of stick or thick paste material
specifically designed for repair of galvanizing, as approved.
3.3.2
Shop Cleaning and Painting
3.3.2.1
Cleaning
Clean steel and iron work by power wire brushing or other approved manual
or mechanical means, for removal of rust, loose paint, scale, and
deleterious substances. Wash cleaned surfaces which become contaminated
with rust, dirt, oil, grease, or other foreign matter, with solvents until
thoroughly clean. Cleaning steel embedded in concrete is not required.
3.3.2.2
Painting Steel or Iron Surfaces
[Apply one coat of primer.] [Apply primer to a minimum dry film thickness
of 0.025 mm 1.0 mil.] Apply additional shop coat of specified paint, to
which a small amount of tinting material has been added, on surfaces that
will be concealed in the finished construction or that will not be
accessible for finish painting. Accomplish painting in dry weather or under
SECTION 08900
Page 31