Management System (RMS) are: "AE" for
Architect-Engineer; "DO" for District Office
(Engineering Division or other organization in the
District Office); "AO" for Area Office; "RO" for
Resident Office; and "PO" for Project Office. Codes
following the "G" typically are not used for Navy
projects.
Submittal items not designated with a "G" are
considered as being for information only for Army
projects and for Contractor Quality Control approval
for Navy projects.
**************************************************************************
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are [for Contractor Quality Control
approval.][for information only. When used, a designation following the
"G" designation identifies the office that will review the submittal for
the Government.] The following shall be submitted in accordance with
Section 01330 SUBMITTAL PROCEDURES:
SD-03 Product Data
Fragment Retention Film
Cleaning
Manufacturer's data consisting of catalog cuts, brochures,
circulars, and a list of glazing compounds and/or gaskets known to
be incompatible with the fragment retention film.
Manufacturer's application and cleaning instructions for
fragment retention film.
A statement that the fragment retention film supplied was
manufactured using the same materials and process as the material
tested. A statement that the adhesive contains ultraviolet
inhibitors which limit ultraviolet transmission to not more than 8
percent of the radiation between 300 and 380 nanometers. A
statement that the film manufacturer or manufacturer's
representative trained the personnel who will apply the film.
SD-04 Samples
Fragment Retention Film[; G][; G, [_____]]
A sample consisting of a minimum 200 by 275 mm 8 inch by 11 inch
section of fragment retention film including the adhesive layer.
SD-06 Test Reports
Fragment Retention Film[; G][; G, [_____]]
Certified test reports including analysis and interpretation of
test results. Each report shall identify the manufacturer, the
specific product name, the film thickness, the adhesive type and
thickness, and the glass type and thickness. Test reports shall
clearly identify the methods used and shall include the results
recorded.
SECTION 08850
Page 4