]PART 3
EXECUTION
3.1
PREPARATION
Preparation, unless otherwise specified or approved, shall conform to
applicable recommendations in the GANA Glazing Manual, GANA Sealant Manual,
SIGMA TB-3001, SIGMA TM-3000, and manufacturer's recommendations.
Determine the sizes to provide the required edge clearances by measuring
the actual opening to receive the glass. Grind smooth in the shop glass
edges that will be exposed in finish work. Leave labels in place until the
installation is approved, except remove applied labels on heat-absorbing
glass and on insulating glass units as soon as glass is installed. Securely
fix movable items or keep in a closed and locked position until glazing
compound has thoroughly set.
3.2
GLASS SETTING
Shop glaze or field glaze items to be glazed using glass of the quality and
thickness specified or indicated. Glazing, unless otherwise specified or
approved, shall conform to applicable recommendations in the GANA Glazing
Manual, GANA Sealant Manual, SIGMA TB-3001, SIGMA TM-3000, and
manufacturer's recommendations. Aluminum windows, wood doors, and wood
windows may be glazed in conformance with one of the glazing methods
described in the standards under which they are produced, except that face
puttying with no bedding will not be permitted. Handle and install glazing
materials in accordance with manufacturer's instructions. Use beads or
stops which are furnished with items to be glazed to secure the glass in
place.
3.2.1
Sheet Glass
Cut and set with the visible lines or waves horizontal.
3.2.2
Patterned Glass
Set glass with one patterned surface with smooth surface on the weather
side. When used for interior partitions, place the patterned surface in
same direction in all openings.
3.2.3
Insulating Glass Units
Do not grind, nip, or cut edges or corners of units after the units have
left the factory. Springing, forcing, or twisting of units during setting
will not be permitted. Handle units so as not to strike frames or other
objects. Installation shall conform to applicable recommendations of SIGMA
TB-3001 and SIGMA TM-3000.
3.2.4
Installation of Wire Glass
Install glass for fire doors in accordance with installation requirements
of NFPA 80.
3.2.5
Installation of Heat-Absorbing Glass
Glass shall have clean-cut, factory-fabricated edges.
Field cutting will
not be permitted.
SECTION 08800
Page 25