3.5
EQUIPMENT SCHEDULES
The equipment schedules for locking control panels contained in this
section of the specifications represent the type of control functions and
status indication devices required in each locking control panel. Switches
and LEDs shall conform to the requirements for control devices and visual
indicators as specified.
**************************************************************************
NOTE: Panel schedule is a sample to be used as a
guide by the writer for developing locking panel.
Information on the schedules should be as follows:
the name of locking control panel, type (graphic or
linear), mounting (metal control cabinet), and
location. Also list the function (e.g., press to
test switch, silence switch, interlock bypass,
interlock active, etc.) and quantity. These
functions are individually described in this
section. Under "REMARKS" include a brief
description of the function. Finally, list the
quantity and type of all security and builders
hardware controlled or monitored by the locking
control panel. Refer to architectural door schedule
for type of door hardware.
**************************************************************************
--- EQUIPMENT SCHEDULE ---
Locking Control Panel: Female Area
Type: Graphic
Mounting: Metal Cabinet
Location: Female Control Area
DEVICE REQUIREMENTS
___________________________________________________________________________
Quantity
Remarks
Type or Function
___________________________________________________________________________
1
Press to Test
Illuminates all LED's on panel.
1
Signal Silence
Silences all audible signals.
1
Interlock Bypass
Disables the interlock
capability so that any
number of doors may be open
at one time.
5
Cell Call-in
1
Shower Call-in
3
Smoke Detector
Duct Chase Mounted)
1
Group Unlock
Unlocks all cell and shower doors
SECTION 08745
Page 18