glazing.
3. Sizes and types of windows; metal and wood
subframes, casings, or stools, if any; and hardware.
4. Sizes, location, and swing of ventilators;
direction of slide for sliding ventilators; location
and details of fixed sash.
5. Typical window sections and details. Show glass
thickness. Show special glazing, if any.
6. Method of anchoring windows; size and types of
clips, anchors, screws, or other fasteners.
7. Details of nonstructural mullions and mullion
covers; detail of anchoring and reinforcing
nonstructural mullions at windows to receive window
cleaner anchors.
8. Number of window cleaner anchors required and
locations.
9. Locations of windows designated as forced entry
resistant, if any.
**************************************************************************
PART 1
GENERAL
1.1
REFERENCES
**************************************************************************
NOTE: Issue (date) of references included in
provided by the latest guide specification. Use of
SpecsIntact automated reference checking is
recommended for projects based on older guide
specifications.
**************************************************************************
The publications listed below form a part of this specification to the
extent referenced. The publications are referred to within the text by the
basic designation only.
ALUMINUM ASSOCIATION (AA)
AA DAF-45
(2003) Designation System for Aluminum
AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)
AAMA 101
(2002) Voluntary Specifications for
Aluminum, Vinyl (PVC) and Wood Windows and
Glass Doors
AAMA 2603
(2002) Voluntary Specification,
Performance Requirements and Test
Procedures for Pigmented Organic Coatings
SECTION 08581
Page 4