OPTIONAL PERFORMANCE CLASSES ENGLISH
*A
*B
Water
Optional
Applicable
Design
Structural
Performance
Product
Pressure Test Pressure
Test Pressure
Class
Designation
lb/ft sq.
lb/ft sq.
lb/ft sq.
R,C,HC
AW
__________________________________________________________________
30
R,LC
30.0
45.0
4.50
35
R,LC,C
35.0
52.5
5.25
40
R,LC,C
40.0
60.0
6.00
45
R,LC,C,HC,AW
45.0
67.5
6.75
50
R,LC,C,HC,AW
50.0
75.0
7.50
55
R,LC,C,HC,AW
55.0
82.5
8.25
11.0
60
R,LC,C,HC,AW
60.0
90.0
9.00
12.0
65
R,LC,C,HC,AW
65.0
97.5
9.75
12.0
70
R,LC,C,HC,AW
70.0
105.0
10.50
12.0
75
R,LC,C,HC,AW
75.0
112.5
11.25
12.0
80
R,LC,C,HC,AW
80.0
120.0
12.00
12.0
85
R,LC,C,HC,AW
85.0
127.5
12.00
12.0
90
R,LC,C,HC,AW
90.0
135.0
12.00
12.0
*A.
Design pressure = Performance Class
*B.
Structural test pressures shown are for both positive and
negative loads.
3. For projects which require security windows,
refer to AR 190-51 "Security of Army Property at
Unit and Installation Level" and Section 13958
FORCED ENTRY RESISTANT COMPONENTS.
4. For projects which require fire-rated windows to
meet UL and NFPA requirements, specify a steel type
unit as specified in Section 08510 STEEL WINDOWS;
aluminum windows are not approved for this purpose.
5. For basements, projected windows shall be the
inward swinging (project-in) type.
6. The hardware specified is typical for each
window type. Refer to manufacturer's catalog for
optional hardware selections.
7. Double glazed windows with a specified
specified for occupied buildings such as barracks,
medical facilities, administration buildings, etc.
The CRF is a rating number, obtained under test
conditions, that predicts the point at which
frame. Where outside temperature and inside
problem, the appropriate CRF should be inserted in
the space provided.
8.
For Environmental Control windows, the designer
SECTION 08520A
Page 13