Architect-Engineer; "DO" for District Office
(Engineering Division or other organization in the
District Office); "AO" for Area Office; "RO" for
Resident Office; and "PO" for Project Office. Codes
following the "G" typically are not used for Navy
projects.
Submittal items not designated with a "G" are
considered as being for information only for Army
projects and for Contractor Quality Control approval
for Navy projects.
**************************************************************************
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for [Contractor Quality Control
approval.] [information only. When used, a designation following the "G"
designation identifies the office that will review the submittal for the
Government.] The following shall be submitted in accordance with Section
01330 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Aluminum Windows
Insect Screens
Drawings indicating elevations of window, rough-opening
dimensions for each type and size of window, full-size sections,
thicknesses of metal, fastenings, methods of installation and
anchorage, connections with other work, type of wall construction,
size and spacing of anchors, method of glazing, types and
locations of operating hardware, mullion details, weatherstripping
details, [screen details including method of attachment,] [window
cleaner anchor details], and window schedules showing locations of
each window type.
SD-03 Product Data
Aluminum Windows
Manufacturer's descriptive data and catalog cut sheets.
instructions.
SD-04 Samples
Aluminum Windows
Submit [three][_____] color samples of the specified finishes.
SD-06 Test Reports
Aluminum Windows
Reports for each type of aluminum window attesting that
identical windows have been tested and meet all performance
requirements established under paragraph WINDOW PERFORMANCE.
SD-07 Certificates
SECTION 08520A
Page 6