a.
Chemically clean and bonderize windows. Apply dip coat of epoxy
primer baked on for not less than 15 minutes at not less than 149
degrees C 300 degrees F, followed by finish coat of alkyd-amine
enamel of not less than 0.025 mm one mil thickness, baked on for
15 minutes at not less than 149 degrees C 300 degrees F.
b.
Finish color coating to be selected from manufacturer's standard
color chart.
c.
Touch up abraded surfaces with enamel as specified for factory
finish.
2.9
WINDOW TYPES
Conform to SWI SWS. Provide combinations, types and sizes indicated. Each
window shall consist of a unit including [subframe,] [frame,] sash,
hardware, [mullions,] trim, [casing,] [insect screen,] [storm units,] and
anchors. Windows indicated to have screens [or storm units] shall be
designed to accommodate items to be furnished.
2.9.1
Awning Windows
Heavy Intermediate materials in group of top-hinged or projected
out-swinging ventilators:
2.9.1.1
Operators
**************************************************************************
NOTE: Select applicable paragraph(s) from the
following:
**************************************************************************
**************************************************************************
NOTE: Specify push-bar operators in lieu of rotary
hand crank operation wherever feasible. Experience
indicates that rotary hand cranks require excessive
maintenance and, in most cases, will not withstand
continued hard usage. In the event push-bar
operation is not feasible, specify removable
crankhandles. Remote and group operation of windows
may require rotary crankhandle operation. See
paragraph "Special Operators."
**************************************************************************
[Control shall be simultaneous by means of cam-type lever handle fastener
for hand push-pull operation. For windows with screens, provide with
underscreen push bar operators. For operators more than 2 meters 6 feet
above floor, provide with hardware designed for pole operation.]
manually operated by bronze [removable] crankhandle, providing positive
adjustment and holding of vents in any position from fully open to fully
closed. Operator shall securely close ventilators on both sides of window
with machine-cut case-hardened steel gears in steel housing with smooth
lacquer finish.]
SECTION 08510