inhibitor in lieu of galvanizing. Galvanizing of exposed portions of
concrete anchors, non stainless steel fasteners, and hardware other than
factory finished hardware shall conform to ASTM A 153/A 153M or other
approved methods.]
2.4.5
Clearance
[The clearance between the seated steel surfaces of structural steel doors
and frames shall not exceed 1.6 mm 1/16 inch.] [The lateral clearance
between flush mounted structural steel doors and frames shall not exceed
[6] [_____] mm [1/4] [_____] inch at the head and jambs and the clearance
between the meeting edges of pairs of doors shall not exceed [13] [_____]
mm [1/2] [_____] inch.] [The lateral clearance between hollow metal doors
and frames shall not exceed 3 mm 1/8 inch at the head and jambs and the
clearance between the meeting edges of pairs of doors shall not exceed 6 mm
1/4 inch.] The clearance between the door bottom and threshold shall not
exceed 19 mm 3/4 inch.
2.5
BLAST DOOR ASSEMBLIES
**************************************************************************
NOTE: The assembly paragraphs provided for
structural steel, reinforced concrete, and hollow
metal doors will be repeated and edited as many
times as required to specify all door assemblies.
The door designations will then be referenced in the
door schedule on the drawings. Items shown on the
drawings will not be duplicated in the door assembly
paragraphs. The door assembly paragraphs are
pre-edited to show normal use and hardware
availability; e.g., thermal insulation, sound
rating, and mortise locks are omitted for structural
steel and reinforced concrete doors, Type 2 hinges
are normally used for reinforced concrete doors and
thus are shown without brackets, etc.
**************************************************************************
2.5.1
Door [_____]; Steel
**************************************************************************
NOTE: Coordinate with paragraphs DESCRIPTION and
BLAST DOOR ASSEMBLIES.
**************************************************************************
2.5.1.1
Type
Type shall be [structural steel] [double structural steel door with [fixed]
[or] [removable] mullion] [,] [galvanized] [,] [and] [fire-rated].
2.5.1.2
Overpressure
Overpressure shall be [_____] kPa psi [with a [_____] millisecond duration]
in the [seating] [unseating] direction [and [_____] kPa psi [with a [_____]
millisecond duration] in the unseating direction]. The [shock and gas
overpressure] [overpressure] waveform shall be as indicated.
2.5.1.3
Fragment
**************************************************************************
SECTION 08390
Page 25