PART 3
EXECUTION
3.1
INSTALLATION
manufacturer's instructions. Anchors and inserts for guides, brackets,
hardware, and other accessories shall be accurately located. Upon
completion, doors shall be free from warp, twist, or distortion. Doors
shall be lubricated, properly adjusted, and demonstrated to operate freely.
Fire-door installation shall be in conformance with NFPA 80 for the class
indicated and the manufacturer's instructions.
3.2
FIELD FINISHING
Doors to receive field finishing shall be factory primed, as required, and
then shall be finished in accordance with Section 09900 PAINTS AND
COATINGS. Color shall be [in accordance with Section 09915 COLOR SCHEDULE]
[_____].
3.3
CLEANING
Aluminum and stainless steel doors shall be cleaned in accordance with
manufacturer's approved instructions.
3.4
TESTS
The fire doors shall be drop tested in accordance with NFPA 80 to show
proper operation and full automatic closure and shall be reset in
accordance with the manufacturer's instructions. A written record of
initial test shall be provided to the Contracting Officer.
-- End of Section --
SECTION 08331A