USACE / NAVFAC / AFCESA
UFGS-07612N (September 1999)
------------------------------
Preparing Activity: NAVFAC
Replacing without revision
NFGS of same number and date
UNIFIED FACILITIES GUIDE SPECIFICATIONS
References are in agreement with UMRL dated 23 June 2005
**************************************************************************
SECTION 07612N
ALUMINUM STANDING SEAM ROOFING
09/99
**************************************************************************
NOTE: This guide specification covers the
requirements for aluminum standing seam roofing.
Comments and suggestions on this guide specification
are welcome and should be directed to the technical
proponent of the specification. A listing of
technical proponents, including their organization
designation and telephone number, is on the Internet.
Recommended changes to a UFGS should be submitted as
a Criteria Change Request (CCR).
Use of electronic communication is encouraged.
Brackets are used in the text to indicate designer
choices or locations where text must be supplied by
the designer.
**************************************************************************
**************************************************************************
NOTE: On the drawings, show:
1.
Design loads.
2.
Roof slope (minimum one in 24 1/2 inch per foot).
3.
Line(s) of fixity.
4.
Supporting structural framework.
5. Track spacing and attachment details, when
applicable.
6. Attachment clip spacing (list capacity of each
type in spec).
7.
Flashing support and fastening spacing.
8. Roof venting. (Pay particular attention to
preventing infiltration of wind-driven rain).
SECTION 07612N
Page 3