submittal is sufficiently important or complex in
context of the project.
For submittals requiring Government approval on Army
projects, a code of up to three characters within
the submittal tags may be used following the "G"
designation to indicate the approving authority.
Codes for Army projects using the Resident
Management System (RMS) are: "AE" for
Architect-Engineer; "DO" for District Office
(Engineering Division or other organization in the
District Office); "AO" for Area Office; "RO" for
Resident Office; and "PO" for Project Office. Codes
following the "G" typically are not used for Navy
projects.
Submittal items not designated with a "G" are
considered as being for information only for Army
projects and for Contractor Quality Control approval
for Navy projects.
**************************************************************************
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are [for Contractor Quality Control
approval.][for information only. When used, a designation following the
"G" designation identifies the office that will review the submittal for
the Government.] The following shall be submitted in accordance with
Section 01330 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Copper Roof System[; G][; G, [_____]]
Design and erection drawings containing data necessary to
clearly describe design, materials, sizes, layouts, seam
configuration, construction details, provisions for thermal
movement, line of panels, fastener sizes and spacings, sealants
and installation procedures.
SD-03 Product Data
Sealant
Descriptive information.
Qualifications
Qualifications of the manufacturer, installer, and field
representative.
SD-04 Samples
Accessories[; G][; G, [_____]]
One sample of each type of flashing, trim, closure, cap and
similar items. Size shall be sufficient to show construction and
configuration.
SECTION 07610