shall also cover the blow-off at wind gusts up to, and including, [_____]
km/hour mph.
PART 2
PRODUCTS
2.1
MATERIALS
**************************************************************************
NOTE: Edit these paragraphs to meet project
requirements.
**************************************************************************
2.1.1
Existing Clay Tile
Intact and serviceable existing clay tiles shall be salvaged and reused
whenever possible. New clay tiles being incorporated into existing clay
tile roofs shall match existing as closely as possible. Clay tiles from
the same manufacturer as the original shall be used if possible.
2.1.2
Clay Roofing Tile
Clay roofing tile shall be minimum Grade 1 tile conforming to ASTM C 1167.
Tile shall be [one-piece barrel] [two-piece barrel] [flat shingle]
[interlocking shingle] type in the following pattern: [_____]. Tile shall
be [glazed] [unglazed].
2.1.2.1
Colors
Clay tile color shall be [in accordance with Section 09915 COLOR SCHEDULE]
[_____].
2.1.2.2
Fittings
Clay tile fittings shall be of the following types as required by
manufacturer's instructions: eave - [eave closure] [under eave]; gable -
[end band] [gable rake]; ridge - [ridge] [closed ridge end] [ridge/hip
terminal]; hip - [cut hip] [hip roll] [hip starter] [ridge/hip terminal];
valley - [cut valley] [closed valley].
2.1.3
Underlayment Membrane
An underlayment membrane shall be furnished on surfaces to be covered with
tile. Membrane shall consist of [asphalt-saturated felt] [and] [high
strength composite self-adhering membrane].
2.1.3.1
Roofing Felt
Roofing felt shall be asphalt-saturated rag felt, Type II, No. 30 asphalt
felt in accordance with ASTM D 226.
2.1.3.2
Elastomeric Membrane Underlayment
Elastomeric membrane shall be a cold applied composite self-adhering
membrane, minimum 0.10 mm 0.004 inch thick, high strength polyethylene film
with slip resistant embossing, coated on one side with a thick layer of
adhesive-consistency rubberized asphalt, interwound with a disposable
silicone coated release sheet. The tensile strength and elongation values
shall be not less than 1724 kPa 250 psi when tested in accordance with ASTM
D 412 and pliability shall be unaffected when tested in accordance with
SECTION 07320A
Page 7