3. Detail at eave/rake corner of roof including
underlayment, drip edge, starter strip, shingle
exposure, shingle courses, and fastener placement.
**************************************************************************
PART 1
GENERAL
1.1
REFERENCES
**************************************************************************
NOTE: Issue (date) of references included in
provided by the latest guide specification. Use of
SpecsIntact automated reference checking is
recommended for projects based on older guide
specifications.
**************************************************************************
The publications listed below form a part of this specification to the
extent referenced. The publications are referred to within the text by the
basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM D 1970
(2001) Self-Adhering Polymer Modified
Bituminous Sheet Materials Used as Steep
Roofing Underlayment for Ice Dam Protection
ASTM D 224
(1989; R 1996) Smooth-Surfaced Asphalt
Roll Roofing (Organic Felt)
ASTM D 226
(1997a) Asphalt-Saturated Organic Felt
Used in Roofing and Waterproofing
ASTM D 249
(1989; R 1996) Asphalt Roll Roofing
(Organic Felt) Surfaced with Mineral
Granules
ASTM D 3018
(2003) Class A Asphalt Shingles Surfaced
With Mineral Granules
ASTM D 3462
(2004) Asphalt Shingles Made From Glass
Felt and Surfaced with Mineral Granules
ASTM D 41
(1994; R 2000e1) Asphalt Primer Used in
Roofing, Dampproofing, and Waterproofing
ASTM D 4586
(2000) Asphalt Roof Cement, Asbestos-Free
ASTM D 4869
(2004) Asphalt-Saturated Organic Felt
Underlayment Used in Steep Slope Roofing
NATIONAL ROOFING CONTRACTORS ASSOCIATION (NRCA)
NRCA Shingle Manual
1996 Asphalt Shingle Roofing Manual
SECTION 07311
Page 4